Can you check my Mining Sample?
We can check some elements but cannot do raw earth elements due to lack of available standards. If you can arrange for a standard solution or sample of known concentration, we can carryout analysis on our ICP provided you have a number of samples and such tests are needed routinely.
Top
Which elements can you analyze for out Copper sample?
We are pleased to inform you that we can analyze your copper samples for its Purity as well as for impurities such as S P As Ni Co Zn Pb Sn Bi Sb Si Ag etc. as per your QA requirements.
Top
Can you analyze our Sodium Silicate Glass sample?
We can take up the analysis of your Sodium Silicate Glass sample in our material testing laboratory and our charges for the same shall be Rs. 1150/- per sample plus applicable service tax.
Top
Can you analyze any given powder?
We can analyze only INORGANIC Powders and our charges for the same shall be about US $ 50 per sample (Rs. 1500/- to Rs. 2000/-). If your sample is Organic, then we cannot analyze it. Please allow 2 – 3 weeks time and 12.24% Service Tax on our analysis charges.
Top
Can you detect gases like Oxygen & Hydrogen?
TCR does not have facilities to check gases like Oxygen & Hydrogen.
Top
Can you analyze a lithium silicate (Li2O-SiO2) glass powdered sample?
We regularly analyze inorganic powders such as Palladium Oxide, Copper, Sulphate, Zirconium Oxide, Calcium Silicate, Titanium Oxide, Alumina, Sand, IronOre etc. We therefore can analyze lithium Silicate samples also. You may send us your samples and we can certainly provide you complete analysis as long as these are inorganic compounds. Our charges for such complete analysis will be US $ 100 per sample. We need 2 to 3 weeks time to complete such a job.
Top
Can you test polymers?
We regret to inform you that we do not have requisite facilities to test Polymers.
Top
We wish to carry out testing on jewellery in India. Can you help?
TCR Engineering is pleased to inform you that we can analyze your jewellery sample for the following elements:
Pure Gold Material - Pb, Al, Fe, S, As & Sb
Copper - As ,Fe, Pb, Sb & S
Silver - Pb, Sb & S
In addition to the above commonly requested elements for jewellery testing, we can test most other elements as well. Please contact us for further information.
Top
Can exact 5 or ppm level of hexavalent chromium be checked at TCR?
We regret to inform you that hexavalent chromium cannot be determined by Colorimetry or Atomic absorption spectrometry. It can only be done by XRD method which TCR presently does not have facilities to undertake.
Top
Can you determine %iron content test on a silica sand sample?
We can certainly take up your job and give you %Fe in Silica Sand sample. Our charges including Service Tax will be US $ 10 per sample. Please note that it would take us one week’s time to complete the job. We will need a minimum 20gm Powder material per sample.
Top
Can you conduct an analysis of Sodium Hypochlorite 12.5%, and tell us if the trace metal analysis for Fe, CU, Mn and Ni fall within given specifications?
We can undertake analysis of Fe, Cu, Mn, and Ni. The cost of analysis will be US $16 plus a 12.24% service tax.
Top
Can you conduct tests on limestone for the mineral composition?
TCR Engineering can conduct test for Moisture Content and Chemical Analysis of Lime Stone. Our charges per sample would be US $60 plus 12.24% Service Tax and we need approximately. one week's time to complete the test. We can also provide sampling/ inspection (drawing sample) services at your vendor's site, at an extra cost. Please let us know if you need these services also for pre shipment inspection.
Top
Do you have any testing facility to find out the content of lead and cadmium in food grade PVC in India?
We regret to inform you that we do not have facilities to undertake the job as requested by you.
Top
Can you check the all-chemical elements of S.G. Iron Casting?
Yes we can check all the chemical elements of S.G. Iron Castings on our LECO GDS (Glow Discharge) Spectrometer. Our charges will be Rs. 400 for first 8 elements and Rs. 60 for each additional element. Service tax of 12.24% will be extra.
Top
Do you perform analysis of rare earth elements?
We regret that we may not be able to undertake analysis of your rare earth elements due to lack of standards available with us. We may look into the possibility if you provide us such standards for the calibration of the instrument.
Top
Please elaborate about the GDS 500 Spectrometer for cast iron and the elements that it can analyze?
At TCR, our spectrometer - LECO GDS 500 can perform analysis of elements like C S P Mn Si Cr Ni Mo Cu V Al Ti Mg Sn Pb W etc. on cast iron samples.
Top
We would appreciate if you could give us quotations for testing charges under IS:2062 for Molybdenum and Vanadium?
Our charges for analyzing Mo & V in IS 2062 shall be Rs. 120/- for 1st element + Rs. 80/- for each additional element i.e. Rs. 200/- per sample. A 12.24% Service Tax shall also be applicable on total invoice value.
Top
Can you determine the composition of Ti-TiB composition in a Titanium composite sample?
We can analyze Ti & Ti alloy samples for their chemical composition in our lab.
Top
Can you assist is our analysis of reference alloys?
TCR Engineering Services is pleased to inform you that we can undertake analysis of reference alloys. We have been doing so for Brammer Standards Company, USA and MBH Analytical Ltd, UK. Brammer Standard produces and distributes thousands of analytical reference materials. MBH Analytical is one of the world's major producers and supplier of Certified Reference Materials.
Please note that analysis of reference material is done to a greater precision than routine commercial analysis and therefore it costs more than our routine charges.
Top
Can you find impurities down to 10's of ppm in a LAST thermoelectric sample in powder form?
TCR is pleased to inform you that we can analyze such samples for their elemental analysis. We expect to find Al2O3, SiO2, CaO, BaO as well as some impurities from the raw materials, namely: Se, Cu, Bi. We will report content of Al, Bi, Ca, Bo etc. and they can be expressed as Al2O3 etc. We do have an ICP spectrometer which can be used for such purpose and we do analyze sample for this kind of concentration. The cost of such analysis will be approx. US $ 6.00 per element per sample + 12.24% Service Tax.
Top
Can you let us know the chemical composition and grade of our 1/2" diameter pipe Inconel sample?
There are various grades of inconel such as 625, 600, 601, 800, 825 etc. and since our testing charges are based on number of elements tested, we may not be able to give you exact charges but it would be in the range of Rs. 1000/- to Rs. 1500/- per sample. Charges are Rs. 200/- for the 1st element and Rs. 100/- for each additional element plus 12.24% Service Tax. We need approx 1" long tube sample and will need 4 days to complete the job.
Top
Can you analyze the following elements in our copper cathode button samples(Se, Te, Bi, Cr, Mn, Sb, Cd, As, P, Pb, S, Sn, Ni, Fe, Si, Co, Zn, and Ag) for the range of ppm to Sub ppm level)?
Yes, it would be possible for us to carryout analysis of all the elements listed by you. We need approx. 1 week time to complete the job. Our charges will depend on number of elements analyzed. For 18 elements it does work out to Rs. 3600/- plus 12.24% Service Tax.
Top
I have Graphite based compound & wish to know its constituents with percentage contents.?
Charges will be approximate Rs. 2500/- plus 12.24% Service Tax and it would take approximate 2 week's time to complete the job. Please send 20gms powder.
Top
Kindly send us a budgetary quotation with the taxes for the analysis of Cl and P in the Zirconium - Niobium alloy sample material?
We are pleased to inform you that we can undertake chemical testing on your sample and charges for the same shall be Rs. 335/- (US $10) per sample plus a 12.24% Service Tax.
Top
Can you test sponge iron?
Yes we can test sponge iron for Analysis of C, Fe(Total), Fe (Metallic), S, and P. Our charges will be Rs. 600/- per sample plus 12.24% Service Tax. We cannot provide Size Analysis, Degree of Metallization and Non Magnetic testing.
Top
Can you perform analysis Collagen (Porcine) of trace elements in biological matrix by ICP?
TCR can perform analysis of trace elements in Collagen (Porcine) to detect Copper, Iron, Manganese, Seleninem, Zinc, Arsenic, Lead, Cadminm and Chrominum. Please note that we need about 5 - 10 gm sample quantity and the rate for each of such sample shall be Rs. 200/- per element + 12.24% Service Tax.
Top
What are your charges for Testing Iron Ore in your lab in Mumbai, India?
Our charges for testing Iron Ore are % Fe at Rs. 300/- per sample. Each additional element such as SiO2, MnO, C, S etc at Rs. 200/- each per sample. A Service Tax of 12.24% is applicable.
Top
Can you test pigment paste (dry pigment powder dispersed in a polyester resin) for 'LEAD CONTENT'?
We can analyze lead in PPM level by use of ICP method. We will however have to standardize the method for your organic sample and therefore we will undertake your job only if you have a regular requirement and number of samples to be tested are at least 3 or 4 in every lot.
Top
Can you perform chemical Analysis of Lead Sticks?
We are pleased to inform you that we can undertake the analysis and our charges for Chemical Analysis (Non ferrous) will be Rs. 200 for the first element and Rs. 100 per element for each additional element. A 12.24% service tax is extra.
Top
Do you have Cobalt base spectro analysis facility?
We do not have Cobalt base spectro analysis facility.
Top
I want to know if the chemical analysis of a copper alloy sample is possible or not?
We can analyze your sample for all elements including Cu, Fe, Pb, Ni. Ag, Be, Au, Zn, Sn and our charges will be US $ 5 for the first element and Us $3 for each additional element plus applicable Service Tax. We would appreciate if you can list all impurities you need when you send your sample. Cu will be analyzed by electrolysis method. Please note that we will not be analyzing Oxygen.
Top
Can you perform chemical analysis on Bauxite?
You will need to send us a Minimum 25 gm sample for us to carry out chemical analysis on your Bauxite samples.
Top
We are sending a Carbon Steel test coupon. Please carry out Tensile and chemical anlysis for Copper, Nickel, Chromium, Molybdenum, Vanadium, Columbium and Titanium?
Thank you for sending us the sample. We can carry out the tensile test at a cost of US $5.00 per sample. Chemical Analysis for upto 12 elements will cost US $25.00 per sample. A 12.24% service tax is applied on all invoices.
Top
Can you conduct test for Tellurium, Bismuth and Sodium on C-953 Grade material?
Yes, we can undertake chemical analysis for Tellurium, Bismuth and Sodium at our laboratory in Navi Mumbai, India. We can analyze all your impurities in Copper samples.
Top
Can you quote for Nitrogen analysis in our Steel Sample?
Charges for nitrogen analysis are Rs. 200 per sample plus service tax at 12.24%. Please send 25mm X 25mm X 10mm sample size.
Top
Do you conduct ICP analysis of Silver Nitrate electrolyte?
If your sample does not contain any organic mater, than we can analyze it on our ICP. Please note that for such analysis, we have to prepare a program by analyzing certain standards and also do the calibration. This is possible only if you propose to analyze such samples on regular basis. Please inform your expected number of samples per month as well as the elements you need to analyze in each sample. On receipt of this information we shall send you our quotation.
Top
Can you test Fly Ash for Reactive Silica Content as per IS 3812 Part 1?
We regret our inability to do this test.
Top
Can you analyzing the Palladium content in a drug matrix using ICP OES?
We do have an ICP and we do analyze Pd in Palladium Catalysts etc for Chemical Industry. We shall be pleased to undertake your job particularly if it is of routine nature. If your requirement is one time only then we beg to say sorry as we have to develop a procedure for preparation of sample (for elimination of organic matter) and then calibration with various standards.